Today most of the burners are cleaned and the warmth exchanger has been examined for fractures and everything is back in position, including the blower.On to another step. Now, if the service man was value his salt, he checks the most crucial area of the heater, the "limit switch ".There is a control move in every; gasoline, fat, electric, or lp furnace, or boiler.
It's major function is to turn on the fan (usually 200') and closed it down (around 110 or 100'any colder, and you would feel just like there clearly was a draft) and the main job it's is to inform the "fuel valve" to shut down the writers incase the fan fails. It keeps the heater or boiler (boilers also have a "safety comfort device" like heated water heaters) from around heat and beginning a fire.
What the greater people did was draw the blower cord down the restrict change and begin the heater burners. With the blower wire taken off the restrict switch, the blower can't start, and when the furnaces extends to furnaces & boilers 200 degrees, the writers should shut down and not relight again before the furnaces cools and reduces it's heat to about 140 degrees.
Some guys only checked the restrict change by turning the dial on the limit change and blower controls before the writers closed off. I enjoyed using the wire down the restrict change and screening it this way because it was more true to life functioning conditions in the event of blower failure. One of the last things, and just like crucial as checking the restrict move, was to check the "flue pipe" to ensure it, or the chimney, hasn't been clogged by soot or birds.
It was not uncommon to find dead chickens in the flue. Some even managed to get in to people's basements. That does not happen anymore with the new furnaces.And the very last thing that has been done was to check for fuel leaks. Today's furnaces and boilers don't need the kind of attention from the service man like furnaces of the past did. Of all contemporary furnaces all that needs to be checked may be the "fire indicator ".
The furnaces of today virtually view themselves. The burners almost never get filthy now a days because they are employed in a mainly closed (80 plus furnaces aren't, however the 90's are) environment. The blower, gas device, and all of the safety controls (including the "limit switch" and "fan move") are run by a world board. The blowers are typical covered today too. They do not even have to be oiled!